Search Results (142 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-27021 1 Nokia 2 G42, G42 Firmware 2026-02-11 7 High
The misconfiguration in the sudoers configuration of the operating system in Infinera G42 version R6.1.3 allows low privileged OS users to read/write physical memory via devmem command line tool. This could allow sensitive information disclosure, denial of service, and privilege escalation by tampering with kernel memory. Details: The output of "sudo -l" reports the presence of "devmem" command executable as super user without using a password. This command allows to read and write an arbitrary memory area of the target device, specifying an absolute address.
CVE-2025-27022 1 Nokia 2 G42, G42 Firmware 2026-02-11 7.5 High
A path traversal vulnerability of the WebGUI HTTP endpoint in Infinera G42 version R6.1.3 allows remote authenticated users to download all OS files via HTTP requests. Details: Lack or insufficient validation of user-supplied input allows authenticated users to access all files on the target machine file system that are readable to the user account used to run the httpd service.
CVE-2025-27023 1 Nokia 2 G42, G42 Firmware 2026-02-11 6.5 Medium
Lack or insufficent input validation in WebGUI CLI web in Infinera G42 version R6.1.3 allows remote authenticated users to read all OS files via crafted CLI commands. Details: The web interface based management of the Infinera G42 appliance enables the feature of executing a restricted set of commands. This feature also offers the option to execute a script-file already present on the target device. When a non-script or incorrect file is specified, the content of the file is shown along with an error message. Due to an execution of the http service with a privileged user all files on the file system can be viewed this way.
CVE-2025-27024 1 Nokia 2 G42, G42 Firmware 2026-02-11 6.5 Medium
Unrestricted access to OS file system in SFTP service in Infinera G42 version R6.1.3 allows remote authenticated users to read/write OS files via SFTP connections. Details: Account members of the Network Administrator profile can access the target machine via SFTP with the same credentials used for SSH CLI access and are able to read all files according to the OS permission instead of remaining inside the chrooted directory position.
CVE-2025-27026 1 Nokia 2 G42, G42 Firmware 2026-02-11 4.9 Medium
A missing double-check feature in the WebGUI for CLI deactivation in Infinera G42 version R6.1.3 allows an authenticated administrator to make other management interfaces unavailable via local and network interfaces. The CLI deactivation via the WebGUI does not only stop CLI interface but deactivates also Linux Shell, WebGUI and Physical Serial Console access. No confirmation is asked at deactivation time. Loosing access to these services device administrators are at risk of completely loosing device control.
CVE-2025-10258 1 Nokia 1 Infinera Dna 2026-02-10 6.3 Medium
Infinera DNA is vulnerable to a time-based SQL injection vulnerability due to insufficient input validation, which may result in leaking of sensitive information.
CVE-2025-9974 1 Nokia 1 Nokia Ont 2026-02-04 8 High
The unified WEBUI application of the ONT/Beacon device contains an input handling flaw that allows authenticated users to trigger unintended system-level command execution. Due to insufficient validation of user-supplied data, a low-privileged authenticated attacker may be able to execute arbitrary commands on the underlying ONT/Beacon operating system, potentially impacting the confidentiality, integrity, and availability of the device.
CVE-2025-65885 2 Nokia, Symwld 15 500, 603, 700 and 12 more 2026-01-09 5.1 Medium
An issue was discovered in the Delight Custom Firmware (CFW) for Nokia Symbian Belle devices on Nokia 808 (Delight v1.8), Nokia N8 (Delight v6.7), Nokia E7 (Delight v1.3), Nokia C7 (Delight v6.7), Nokia 700 (Delight v1.2), Nokia 701 (Delight v1.1), Nokia 603 (Delight v1.0), Nokia 500 (Delight v1.2), Nokia E6 (Delight v1.0), Nokia Oro (Delight v1.0), and Vertu Constellation T (Delight v1.0) allowing local attackers to inject startup scripts via crafted .txt files in the :\Data directory.
CVE-2025-0980 2 Linux, Nokia 2 Linux, Service Router Linux 2026-01-08 6.4 Medium
Nokia SR Linux is vulnerable to an authentication vulnerability allowing unauthorized access to the JSON-RPC service. When exploited, an invalid validation allows JSON RPC access without providing valid authentication credentials.
CVE-2025-26487 2 Infinera, Nokia 3 Mtc-9, Infinera Mtc-9, Infinera Mtc-9 Firmware 2025-12-22 8.6 High
Server-Side Request Forgery (SSRF) vulnerability in Infinera MTC-9 version allows remote unauthenticated users to gain access to other network resources using HTTPS requests through the appliance used as a bridge.
CVE-2025-26488 2 Infinera, Nokia 3 Mtc-9, Infinera Mtc-9, Infinera Mtc-9 Firmware 2025-12-22 7.5 High
Improper Input Validation vulnerability in Infinera MTC-9 allows remote unauthenticated users to crash the service and cause a reboot of the appliance, thus causing a DoS condition, via crafted XML payloads.This issue affects MTC-9: from R22.1.1.0275 before R23.0.
CVE-2025-26489 2 Infinera, Nokia 3 Mtc-9, Infinera Mtc-9, Infinera Mtc-9 Firmware 2025-12-22 6.5 Medium
Improper input validation in the Netconf service in Infinera MTC-9 allows remote authenticated users to crash the service and reboot the appliance, thus causing a DoS condition, via crafted XML payloads.This issue affects MTC-9: from R22.1.1.0275 before R23.0.
CVE-2025-27019 2 Infinera, Nokia 3 Mtc-9, Infinera Mtc-9, Infinera Mtc-9 Firmware 2025-12-22 9.8 Critical
Remote shell service (RSH) in Infinera MTC-9 version R22.1.1.0275 allows an attacker to utilize password-less user accounts and obtain system access by activating a reverse shell.This issue affects MTC-9: from R22.1.1.0275 before R23.0.
CVE-2025-27020 2 Infinera, Nokia 3 Mtc-9, Infinera Mtc-9, Infinera Mtc-9 Firmware 2025-12-22 9.8 Critical
Improper configuration of the SSH service in Infinera MTC-9 allows an unauthenticated attacker to execute arbitrary commands and access data on file system . This issue affects MTC-9: from R22.1.1.0275 before R23.0.
CVE-2023-49565 1 Nokia 2 Cbis, Ncs 2025-09-18 8.4 High
The cbis_manager Podman container is vulnerable to remote command execution via the /api/plugins endpoint. Improper sanitization of the HTTP Headers X-FILENAME, X-PAGE, and X-FIELD allows for command injection. These headers are directly utilized within the subprocess.Popen Python function without adequate validation, enabling a remote attacker to execute arbitrary commands on the underlying system by crafting malicious header values within an HTTP request to the affected endpoint. The web service executes with root privileges within the container environment, the demonstrated remote code execution permits an attacker to acquire elevated privileges for the command execution. Restricting access to the management network with an external firewall can partially mitigate this risk.
CVE-2023-49564 1 Nokia 2 Cbis, Ncs 2025-09-18 8.8 High
The CBIS/NCS Manager API is vulnerable to an authentication bypass. By sending a specially crafted HTTP header, an unauthenticated user can gain unauthorized access to API functions. This flaw allows attackers to reach restricted or sensitive endpoints of the HTTP API without providing any valid credentials. The root cause of this vulnerability lies in a weak verification mechanism within the authentication implementation present in the Nginx Podman container on the CBIS/NCS Manager host machine. The risk can be partially mitigated by restricting access to the management network using external firewall.
CVE-2025-24936 1 Nokia 1 Wavesuite Noc 2025-08-11 9 Critical
The web application allows user input to pass unfiltered to a command executed on the underlying operating system. The vulnerable component is bound to the network stack and the set of possible attackers extends up to and including the entire Internet. An attacker with low privileged access to the application has the potential to execute commands on the operating system under the context of the webserver.
CVE-2025-24937 1 Nokia 1 Wavesuite Noc 2025-08-11 9 Critical
File contents could be read from the local file system by an attacker. Additionally, malicious code could be inserted in the file, leading to a full compromise of the web application and the container it is running on. The vulnerable component is bound to the network stack and the set of possible attackers extends up to and including the entire Internet. The web application allows arbitrary files to be included in a file that was downloadable and executable by the web server.
CVE-2025-24938 1 Nokia 1 Wavesuite Noc 2025-08-11 8.4 High
The web application allows user input to pass unfiltered to a command executed on the underlying operating system. An attacker with high privileged access (administrator) to the application has the potential execute commands on the operating system under the context of the webserver. The vulnerable component is bound to the network stack and the set of possible attackers extends up to and including the entire Internet. Has the potential to inject command while creating a new User from User Management.
CVE-2024-25659 2 Infinera, Nokia 2 Tnms, Transcend Network Management System 2025-07-03 7.2 High
In Infinera TNMS (Transcend Network Management System) 19.10.3, an insecure default configuration of the internal SFTP server on Linux servers allows remote attacker to access files and directories outside the SFTP user home directory.