The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).
Project Subscriptions
| Vendors | Products |
|---|---|
|
Hillrom
Subscribe
|
Connex Central Station
Subscribe
Connex Device Integration Suite Network Connectivity Engine
Subscribe
Connex Integrated Wall System
Subscribe
Connex Spot Monitor
Subscribe
Connex Vital Signs Monitor
Subscribe
Service Monitor
Subscribe
Service Tool
Subscribe
Software Development Kit
Subscribe
Spot Vital Signs 4400
Subscribe
|
Advisories
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2021-14162 | The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00). |
Fixes
Solution
No solution given by the vendor.
Workaround
No workaround given by the vendor.
References
| Link | Providers |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01 |
|
History
No history.
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: icscert
Published:
Updated: 2024-08-03T20:48:16.852Z
Reserved: 2021-02-19T00:00:00
Link: CVE-2021-27408
No data.
Status : Modified
Published: 2021-06-11T17:15:10.637
Modified: 2024-11-21T05:57:56.043
Link: CVE-2021-27408
No data.