An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3.

Project Subscriptions

Vendors Products
Codesys Subscribe
Control For Beaglebone Sl Subscribe
Control For Empc-a\/imx6 Sl Subscribe
Control For Iot2000 Sl Subscribe
Control For Linux Sl Subscribe
Control For Pfc100 Sl Subscribe
Control For Pfc200 Sl Subscribe
Control Rte Sl Subscribe
Control Win Sl Subscribe
Development System Subscribe
Raspberry Pi Subscribe
Runtime Toolkit Subscribe
Advisories
Source ID Title
EUVD EUVD EUVD-2019-18400 An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3.
Fixes

Solution

No solution given by the vendor.


Workaround

No workaround given by the vendor.

History

No history.

Projects

Sign in to view the affected projects.

cve-icon MITRE

Status: PUBLISHED

Assigner: mitre

Published:

Updated: 2024-08-04T21:31:37.591Z

Reserved: 2019-02-22T00:00:00

Link: CVE-2019-9013

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Modified

Published: 2019-08-15T17:15:13.660

Modified: 2024-11-21T04:50:48.770

Link: CVE-2019-9013

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

No data.

Weaknesses