Platform dependent weakness. This issue only impacts iSeries platforms. On these platforms, in BIG-IP (LTM, AAM, AFM, Analytics, APM, ASM, DNS, Edge Gateway, FPS, GTM, Link Controller, PEM, WebAccelerator) versions 14.0.0-14.1.0.1, 13.0.0-13.1.1.3, and 12.1.1 HF2-12.1.4, the secureKeyCapable attribute was not set which causes secure vault to not use the F5 hardware support to store the unit key. Instead the unit key is stored in plaintext on disk as would be the case for Z100 systems. Additionally this causes the unit key to be stored in UCS files taken on these platforms.

Project Subscriptions

Vendors Products
Big-ip Access Policy Manager Subscribe
Big-ip Advanced Firewall Manager Subscribe
Big-ip Analytics Subscribe
Big-ip Application Acceleration Manager Subscribe
Big-ip Application Security Manager Subscribe
Big-ip Domain Name System Subscribe
Big-ip Edge Gateway Subscribe
Big-ip Fraud Protection Service Subscribe
Big-ip Global Traffic Manager Subscribe
Big-ip I10600 Subscribe
Big-ip I10800 Subscribe
Big-ip I11600 Subscribe
Big-ip I11800 Subscribe
Big-ip I15600 Subscribe
Big-ip I15800 Subscribe
Big-ip I2000s Subscribe
Big-ip I2200s Subscribe
Big-ip I4000s Subscribe
Big-ip I4200v Subscribe
Big-ip I5000s Subscribe
Big-ip I5050s Subscribe
Big-ip I5200v Subscribe
Big-ip I5250v Subscribe
Big-ip I5250v Fips Subscribe
Big-ip I7000 Subscribe
Big-ip I7050s Subscribe
Big-ip I7055s Subscribe
Big-ip I7200v Subscribe
Big-ip I7200v-ssl Subscribe
Big-ip I7200v Fips Subscribe
Big-ip I7250v Subscribe
Big-ip I7255s Subscribe
Big-ip Link Controller Subscribe
Big-ip Local Traffic Manager Subscribe
Big-ip Policy Enforcement Manager Subscribe
Big-ip Webaccelerator Subscribe
Big-ip Webaccelerator12.1.1 Subscribe
Advisories
Source ID Title
EUVD EUVD EUVD-2019-16168 Platform dependent weakness. This issue only impacts iSeries platforms. On these platforms, in BIG-IP (LTM, AAM, AFM, Analytics, APM, ASM, DNS, Edge Gateway, FPS, GTM, Link Controller, PEM, WebAccelerator) versions 14.0.0-14.1.0.1, 13.0.0-13.1.1.3, and 12.1.1 HF2-12.1.4, the secureKeyCapable attribute was not set which causes secure vault to not use the F5 hardware support to store the unit key. Instead the unit key is stored in plaintext on disk as would be the case for Z100 systems. Additionally this causes the unit key to be stored in UCS files taken on these platforms.
Fixes

Solution

No solution given by the vendor.


Workaround

No workaround given by the vendor.

History

No history.

Projects

Sign in to view the affected projects.

cve-icon MITRE

Status: PUBLISHED

Assigner: f5

Published:

Updated: 2024-08-04T20:23:22.059Z

Reserved: 2019-01-22T00:00:00.000Z

Link: CVE-2019-6609

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Modified

Published: 2019-04-15T15:29:00.920

Modified: 2024-11-21T04:46:47.907

Link: CVE-2019-6609

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

No data.

Weaknesses