A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
Project Subscriptions
| Vendors | Products |
|---|---|
|
Siemens
Subscribe
|
Simatic Hmi Comfort Outdoor Panels
Subscribe
Simatic Hmi Comfort Outdoor Panels Firmware
Subscribe
Simatic Hmi Comfort Panels
Subscribe
Simatic Hmi Comfort Panels Firmware
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp400f
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp400f Firmware
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp700
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp700 Firmware
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp700f
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp700f Firmware
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp900
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp900 Firmware
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp900f
Subscribe
Simatic Hmi Ktp Mobile Panels Ktp900f Firmware
Subscribe
Simatic Hmi Mp
Subscribe
Simatic Hmi Mp Firmware
Subscribe
Simatic Hmi Op
Subscribe
Simatic Hmi Op Firmware
Subscribe
Simatic Hmi Tp
Subscribe
Simatic Hmi Tp Firmware
Subscribe
Simatic Wincc \(tia Portal\)
Subscribe
Simatic Wincc Runtime
Subscribe
|
Advisories
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2018-5748 | A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. |
Fixes
Solution
No solution given by the vendor.
Workaround
No workaround given by the vendor.
References
History
No history.
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: siemens
Published:
Updated: 2024-08-05T09:14:47.285Z
Reserved: 2018-07-10T00:00:00.000Z
Link: CVE-2018-13812
No data.
Status : Modified
Published: 2018-12-13T16:29:00.290
Modified: 2024-11-21T03:48:07.190
Link: CVE-2018-13812
No data.
OpenCVE Enrichment
No data.
Weaknesses
EUVD