| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper authentication in the Intel(R) SUR software before version 2.4.8902 may allow a privileged user to potentially enable escalation of privilege via network access. |
| An improper authorization vulnerability exists in Rocket.Chat <6.0 that could allow a hacker to manipulate the rid parameter and change the updateMessage method that only checks whether the user is allowed to edit message in the target room. |
| Improper Authentication of RemoteUI of Office / Small Office Multifunction Printers and Laser Printers(*) which may allow an attacker on the network segment to trigger unauthorized access to the product. *:Satera LBP660C Series/LBP620C Series/MF740C Series/MF640C Series firmware Ver.11.04 and earlier sold in Japan. Color imageCLASS LBP660C Series/LBP 620C Series/X LBP1127C/MF740C Series/MF640C Series/X MF1127C firmware Ver.11.04 and earlier sold in US. i-SENSYS LBP660C Series/LBP620C Series/MF740C Series/MF640C Series, C1127P, C1127iF, C1127i firmware Ver.11.04 and earlier sold in Europe. |
| An authentication bypass in Optoma 1080PSTX C02 allows an attacker to access the administration console without valid credentials. |
| An Authentication Bypass Using an Alternate Path or Channel vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface allows Authentication Bypass.
See SEL Service Bulletin dated 2022-11-15 for more details.
|
| An authentication bypass vulnerability exists in the Authentication functionality of Weston Embedded uC-FTPs v 1.98.00. A specially crafted set of network packets can lead to authentication bypass and denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability. |
| Improper authentication in the Intel(R) DCM software before version 5.1 may allow an authenticated user to potentially enable escalation of privilege via network access. |
| Vert.x STOMP is a vert.x implementation of the STOMP specification that provides a STOMP server and client. From versions 3.1.0 until 3.9.16 and 4.0.0 until 4.4.2, a Vert.x STOMP server processes client STOMP frames without checking that the client send an initial CONNECT frame replied with a successful CONNECTED frame. The client can subscribe to a destination or publish message without prior authentication. Any Vert.x STOMP server configured with an authentication handler is impacted. The issue is patched in Vert.x 3.9.16 and 4.4.2. There are no trivial workarounds. |
| GLPI is a free asset and IT management software package. Starting in version 0.80 and prior to version 10.0.17, an administrator with access to the sent notifications contents can take control of an account with higher privileges. Version 10.0.17 contains a patch for this issue. |
|
Use of Password Hash Instead of Password for Authentication in SICK FTMg AIR
FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526
allows an unprivileged remote attacker to use a password hash instead of an actual password to login
to a valid user account via the REST interface.
|
| Nextcloud Server is a self hosted personal cloud system. After an attacker got access to the session of a user or administrator, the attacker would be able to create, change or delete external storages without having to confirm the password. It is recommended that the Nextcloud Server is upgraded to 28.0.12, 29.0.9 or 30.0.2. |
| The Paid Membership Subscriptions – Effortless Memberships, Recurring Payments & Content Restriction plugin for WordPress is vulnerable to Authentication Bypass in all versions up to, and including, 2.13.7. This is due to the pms_pb_payment_redirect_link function using the user-controlled value supplied via the 'pms_payment_id' parameter to authenticate users without any further identity validation. This makes it possible for unauthenticated attackers with knowledge of a valid payment ID to log in as any user who has made a purchase on the targeted site. |
| Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.
|
| Broken Authentication vulnerability discovered in OpenText™ iManager 3.2.6.0200. This
vulnerability allows an attacker to manipulate certain parameters to bypass
authentication.
|
| Osprey Pump Controller version 1.01 could allow an unauthenticated user to create an account and bypass authentication, thereby gaining unauthorized access to the system. A threat actor could exploit this vulnerability to create a user account without providing valid credentials. A threat actor who successfully exploits this vulnerability could gain access to the pump controller and cause disruption in operation, modify data, or shut down the controller. |
| The listed versions of Nexx Smart Home devices could allow any user to register an already registered alarm or associated device with only the device’s MAC address. |
|
Teltonika’s Remote Management System versions prior to 4.10.0 use device serial numbers and MAC addresses to identify devices from the user perspective for device claiming and from the device perspective for authentication. If an attacker obtained the serial number and MAC address of a device, they could authenticate as that device and steal communication credentials of the device. This could allow an attacker to enable arbitrary command execution as root by utilizing management options within the newly registered devices.
|
|
Teltonika’s Remote Management System versions 4.14.0 is vulnerable to an unauthorized attacker registering previously unregistered devices through the RMS platform. If the user has not disabled the "RMS management feature" enabled by default, then an attacker could register that device to themselves. This could enable the attacker to perform different operations on the user's devices, including remote code execution with 'root' privileges (using the 'Task Manager' feature on RMS).
|
| In GeoVision GV-ADR2701 cameras, an attacker could edit the login response to access the web application.
|
| Improper Authentication vulnerability in Progress MOVEit Transfer (SFTP module) can lead to Authentication Bypass.This issue affects MOVEit Transfer: from 2023.0.0 before 2023.0.11, from 2023.1.0 before 2023.1.6, from 2024.0.0 before 2024.0.2. |